1600010800 Compressed air bottle 6 l / 300 bar
Steel, 5/8“ IT = 1,800 l (63.5 cu. ft.) for quick and safe inflation
|
1600010800 |
|
|
1600019900 Compressed air bottle 9 l / 300 bar
Composite, 5/8“ IT = 2,700 l (95.3 cu. ft.) for quick and safe inflation
|
1600019900 |
|
|
1600010500 Compressed air bottle 10 l / 200 bar
Steel, 5/8“ IT = 2,000 l (70.6 cu. ft.) for quick and safe inflation
|
1600010500 |
|
|
1600008400 Dual connector 200 bar
for simultaneous connection of 2 compressed air bottles (200 bar), thread 5/8“
|
1600008400 |
|
|
1600009100 Dual connector 300 bar
for simultaneous connection of 2 compressed air bottles (300 bar), thread 5/8“
|
1600009100 |
|
|
1600026100 Pressure regulator 200 / 300 bar
with max. output pressure of 12 bar
|
1600026100 |
|
|
Pressure regulator 200 / 300 bar (USA)
with max. output pressure of 12 bar
|
1600026200 |
|
|
1600017400 Pressure regulator 200 / 300 bar
with max. output pressure of 20 bar
|
1600017400 |
|
Inflation with blower
|
Name / Description |
Art. no. |
Image |
1523017700 Blower 0.23-0.47 bar/3.3 - 6.8 psi
electrical with 230 V
| Flow rate, max. |
1,800 |
l / min. |
| Flow rate with booster, max. |
2,500 |
l / min. |
| Power, max. |
1,000 |
W |
| Power with booster, max. |
2,000 |
W |
| Mains voltage |
230 / 50 |
V / Hz |
| Dimensions (L x W x H) |
32 x 17 x 26 |
cm |
| Weight |
4.1 |
kg |
|
1523017700 |
|
1523017900 Blower 0.23-0.47 bar/3.3 - 6.8 psi
electrical with 120 V
| Flow rate, max. |
1,800 |
l / min. |
| Flow rate with booster, max. |
2,500 |
l / min. |
| Power, max. |
1,000 |
W |
| Power with booster, max. |
2,000 |
W |
| Mains voltage |
120 / 50 |
V / Hz |
| Dimensions (L x W x H) |
12.5 x 6.6 x 10.1 |
inch |
| Weight |
9 |
lbs |
|
1523017900 |
|
1523029200 Blower 0.23-0.47 bar/3.3 - 6.8 psi, 230 V, IP56
electrical with 230 V
| Flow rate, max. |
1,800 |
l/min. |
| Flow rate with booster, max. |
2,500 |
l/min. |
| Power, max. |
1,000 |
W |
| Power with booster, max. |
2,000 |
W |
| Mains voltage |
230/50 |
V/Hz |
| Dimensions (L x W x H) |
60 x 24 x 35 |
cm |
| Dimensions (L x W x H) |
24 x 9.4 x 14 |
inch |
| Weight |
10 |
kg |
| Weight |
22 |
lbs |
|
1523029200 |
|
|
1523021100 Inflation hose 1.5 m/0.6 inch for blower 0.23 - 0.47 bar
for blower 0.23 - 0.47 bar
|
1523021100 |
|
1523028400 Blower 0.05-0.45 bar/0.7-6.5 psi, 230 V, with automatic pressure monitoring
electrical with 230 V
| Flow rate, max. |
2,000 |
l/min. |
| Power, max. |
2,000 |
W |
| Maximum pressure |
450 |
mbar |
| Maximum pressure |
6.5 |
psi |
| Mains voltage |
230/50 |
V/Hz |
| Dimensions (L x W x H) |
40 x 17 x 26 |
cm |
| Dimensions (L x W x H) |
15.7 x 6.7 x 10.2 |
inch |
| Weight |
5 |
kg |
| Weight |
11 |
lbs |
|
1523028400 |
|
|
1523029400 Inflation hose 1.5 m/0.6 inch for blower with automatic pressure monitoring
for blower with automatic pressure monitoring
|
1523029400 |
|
Deflation
|
Name / Description |
Art. no. |
Image |
|
1700018300 Vacuum adapter
for rapid and complete deflation of the support frame; snap coupling is connected to the air supply source, the pressure should be between 4-8 bar
|
1700018300 |
|
|
1600012000 Adapter
from claw coupling to brass inflation connection
|
1600012000 |
|
Additional windows
|
Name / Description |
Art. no. |
Image |
|
1520020600 Window
with mesh net and cover
|
1520020600 |
|
|
1520025700 Window
with mesh net, cover and additional wind protection foil (polyglass)
|
1520025700 |
|
Ventilation
|
Name / Description |
Art. no. |
Image |
|
1520025800 Ventilation flap
for better ventilation, positioned in the roof
|
1520025800 |
|
Ducts
|
Name / Description |
Art. no. |
Image |
|
1520020500 Duct openings
(additionally) for cables or heating, with velcro and fleece
|
1520020500 |
|
Marking/Logo
|
Name / Description |
Art. no. |
Image |
|
1520022400 print marking
one colour, on the outside (multi-coloured on request)
|
1520022400 |
|
|
1520025600 Cover with print
one colour, 1,300 x 600 mm (multi-coloured on request)
|
1520025600 |
|
Insulation cover
|
Name / Description |
Art. no. |
Image |
|
Insulation cover MT 20
for MT 20, for protection against extreme temperatures
|
1523024600 |
|
Transverse separation walls
|
Name / Description |
Art. no. |
Image |
|
Separation wall, transverse
for MT-Series (all tent sizes) with door
|
1523014100 |
|
Longitudinal separation walls
|
Name / Description |
Art. no. |
Image |
|
MT 20
|
1523014300 |
|
Sluices
|
Name / Description |
Art. no. |
Image |
|
Sluices
(for all MT versions), for connecting tents over the door
|
1523014000 |
|
Ballast tanks
|
Name / Description |
Art. no. |
Image |
|
Ballast tank for MT 20
for improved stability with strong winds, 2 ballast tanks are needed per tent
|
1523018400 |
|
Combination heater GHE 15 M
|
Name / Description |
Art. no. |
Image |
1520004800 Combination heater GHE 15 M
gas / electrical
| Heating power electrical |
3 |
kW |
| Heating power gas |
7 - 14 |
kW |
| Flow rate volumn |
520 |
m³ / h |
| Mains voltage supply |
230 / 50 |
V / Hz |
| Gas consumption, max. |
1.09 |
kg / h |
| Dimensions (L x W x H) |
51 x 21.5 x 33.5 |
cm |
| Dimensions (L x W x H) |
20.1 x 8.5 x 13.2 |
inch |
| Weight, ca. |
10 |
kg |
| Weight, ca. |
22.05 |
lbs |
|
1520004800 |
|
Warm air generator DG 30 S
|
Name / Description |
Art. no. |
Image |
1520004601 Warm air generator DG 30 S
only gas operation
| Heating power |
12 - 29 |
kW |
| Flow rate volumn |
1,000 |
m³ / h |
| Mains voltage supply |
230 / 50 |
V / Hz |
| Gas consumption, max. |
2.25 |
kg / h |
| Dimensions (L x W x H) |
55 x 25 x 41 |
cm |
| Dimensions (L x W x H) |
21.5 x 9.8 x 16 |
inch |
| Weight, ca. |
13.6 |
kg |
| Weight, ca. |
30 |
lbs |
|
1520004601 |
|
Tent heater ATK 25
|
Name / Description |
Art. no. |
Image |
1520028600 Tent heater ATK 25
automatic oil heater
| Heating power |
22.5 |
kW |
| Nominal heating load, max. |
25 |
kW |
| Air flow power |
1,080 |
m³ / h |
| Mains voltage supply |
230 / 50 |
V / Hz |
| Fuel |
a light heating oil / diesel |
|
| Fuel consumption, max. |
2.4 |
kg / h |
| Tank capacity |
40 |
l |
| Exhaust supports Ø |
150 |
mm |
| Dimensions (L x W x H) |
126.5 x 47 x 68.5 |
cm |
| Dimensions (L x W x H) |
49.4 x 18.3 x 26.7 |
inch |
| Weight, ca. |
68 |
kg |
| Weight, ca. |
150 |
lbs |
|
1520028600 |
|
|
1520028700 Damp room thermostat IP 54
including 10 m cable and plug
|
1520028700 |
|
|
1520028800 Warm air hose
Ø 305 mm, L: 7,000 mm
|
1520028800 |
|
|
1520028900 Exhaust tube
1 m
|
1520028900 |
|
|
1520029000 Rain cover
Ø 150 mm, for rain protection
|
1520029000 |
|
Tent heating K 30 T
|
Name / Description |
Art. no. |
Image |
1520040900 Tent heating K 30 T
| Heating power |
29 |
kW |
| Nominal heating load, max. |
32 |
kW |
| Air flow rate |
2,050 |
m³ / h |
| Mains voltage supply |
230/50 |
V/Hz |
| Fuel |
a light heating oil/Diesel |
|
| Fuel consumption, max. |
2.5 |
kg / h |
| Tank capacity |
35 |
l |
| Exhaust supports Ø |
150 |
mm |
| Blow out supports Ø |
2 x 205 |
mm |
| Dimensions (L x W x H) |
145 x 68 x 82 |
cm |
| Dimensions (L x W x H) |
56.5 x 26.5 x 32 |
inch |
| Weight, ca. |
85 |
kg |
| Weight, ca. |
187.5 |
lbs |
|
1520040900 |
|
|
1520017300 Damp room thermostat IP 44
including 10 m cable and plug
|
1520017300 |
|
|
1520017100 Warm air hose
Ø 203 mm, L: 7,600 mm
|
1520017100 |
|
|
1520017200 Exhaust tube
1 m
|
1520017200 |
|
|
1520017400 Rain cover
Ø 150 mm, for rain protection
|
1520017400 |
|
Polarn Heater
|
Name / Description |
Art. no. |
Image |
1520043600 Polarn Heater 4000
For tents up to 17 m²
Heating current Step "Power"* |
4,000 |
Watt |
| Step "Small" |
900 |
Watt |
Fuel consumption Step "Power"* |
0.51 |
l/h |
| Step "Small" |
0.11 |
l/h |
Heating air flow capacity - without counter-pressure Step "Power"* |
185 |
kg/h |
| Step "Small" |
60 |
kg/h |
Electrical power input at 12 V In Operation Step "Power"* |
40 |
Watt |
| Step "Small" |
7 |
Watt |
| When starting |
< 100 |
Watt |
Permissible ambient temperature Operation |
-40 bis +50 |
°C |
| Without operation |
-40 bis +85 |
°C |
Operational range Lower voltage limit |
ca. 10.5 |
Volt |
| Upper voltage limit |
ca. 16 |
Volt |
| Fuel |
Extra light heating oil / Diesel |
|
| Maximum air intake temperature |
+40 |
°C |
| Dimensions (L x W x H) |
36.5 x 22.5 x 46 |
cm |
| Dimensions (L x W x H) |
14.2 x 8.8 x 17.9 |
inch |
| Weight, ca. |
11 |
kg |
| Weight, ca. |
24.3 |
lbs |
| *Further technical data can be found in the operation instructions! |
|
|
|
1520043600 |
|
1520043700 Polarn Heater 8000
For tents up to 40 m².
Heating current Step "Large"* |
8,000 |
Watt |
| Step "Small" |
3,500 |
Watt |
Fuel consumption Step "Large"* |
1.05 |
l/h |
| Step "Small" |
0.4 |
l/h |
| Heating air flow capacity - without counter-pressure |
310 |
kg/h |
Electrical power input at 12 V In operation |
115 |
Watt |
| When starting |
330 |
Watt |
Permissible ambient temperature Operation |
-35 to +60 |
°C |
| Without operation |
-35 to +60 |
°C |
Operational range Lower voltage limit |
ca. 10 |
Volt |
| Upper voltage limit |
ca. 14 |
Volt |
| Fuel |
Extra light heating oil / Diesel |
|
| Maximum air intake temperature |
+60 |
°C |
| Weight, ca. |
26 |
kg |
| Weight, ca. |
57.3 |
lbs |
| *Further technical data can be found in the operating instructions! |
|
|
|
1520043700 |
|